IET Labs
Manufacturer very high-quality instruments at competitive prices while providing a level of service not often found in the industry.
- (516) 334-5959
- (516) 334-5988
- info@ietlabs.com
- 99 Powerhouse Road
#302
Roslyn Heights, New York 11577
United States
-
product
Precision Impedance Meter
1689
The GenRad 1689 Precision Impedance Meter gives you the best performance for your most demanding applications whether they be production test, incoming inspection, component design and evaluation, process monitoring or dielectric measurement. It is a versatile, full function microprocessor-based passive component tester that's available in a rack mountable, (1689M) model.
-
product
High Power Resistance Decade Box
HPRS Series
The HPRS Series resistance decade boxes employ state-of-the-art precision resistors of various types for high accuracy, high stability, and low temperature and power coefficients of- resistance. High-power resistors within the unit are made available without sacrificing other electrical properties.
-
product
Decade Capacitance Box
1412-BC
The wide capacitance range and high resolution of the GenRad 1412-BC decade capacitance box make it exceptionally useful in both laboratory and test shop. Owing to its fine adjustment of capacitance, it is a convenient variable capacitor to use with an Impedance Comparator. The polystyrene dielectric used in the decade steps is necessary for applications requiring low dielectric absorption and constancy of both capacitance and dissipation factor with frequency.
-
product
High Accuracy Decade Capacitance Box
HACS-Z Series
The HACS-Z Series high accuracy capacitance box is capable of meeting exacting requirements for fixed or adjustable calibration capacitance, or any applications requiring precise and stable capacitance values. You can pick the best unit for your application, without overpaying for ranges that you do not require. Models are available with a range of 1 pF - 11,111 F in as few as 3 or as many as 11 decades.
-
product
Capacitance Standard
SCA Series
The SCA Standard Capacitor series are highly stable cost-effective capacitance standards with low temperature coefficient, low losses and a wide range of values of 1 pF - 10,000 F. The cost and flexibility make this our most popular capacitance standard.
-
product
Programmable Capacitance Decade Box
PCS Series
A broad range of laboratory grade programmable capacitance decade boxes for applications requiring a programmable impedance unit controlled manually and by a computer via an IEEE-488, RS-232 interface.
-
product
Plus Precision LCR Meter
7600
The 7600 Plus LCR Meter performs precision impedance measurements over a frequency range of 10 Hz to 2 MHz. The LCR Meter can measure 14 different impedance parameters with 0.05% accuracy, meeting today's requirements for component and material testing. The ease of use and user-friendly menu programming makes the 7600 Plus ideal for applications in product development, incoming inspections, or production line testing.
-
product
Primary Standard Capacitors
GenRad 1404 Series
The GenRad 1404 Series standard capacitors are the standard of choice in metrology labs, and still used today by standards bodies around the world. These capacitors have been designed as primary reference standards of capacitance with which working standards can be compared.
-
product
Digibridge
1659
The GenRad 1659 Digibridge RLC Tester is an easily programmable, microprocessor-based high performance passive component tester. It automatically identifies the type of component under test and measures in the proper range. The result is simple, precise, unambiguous RLC component testing. The GenRad 1659 RLC Digibridge is an instrument for measuring primary parameters of inductance (L), capacitance (C) and resistance (R) and secondary parameters of dissipation factor (D) and quality factor (Q). GenRad designed this single compact unit with maximum flexibility and operator convenience in mind. The simple front panel design of the Digibridge requires less effort to operate. Digital display and user friendly control allows test parameters and limits to be set easily.
-
product
Hipot Current Calibration Load Resistors
HPRS-HIPOT-LOAD
The IET HPRS-Hipot-Load is an excellent replacement for the Fluke 5320A-Load Hipot current calibration load resistors. The IET high power resistive load can be used with the Fluke 5320A Multifunction Electrical Tester Calibrator or standalone. It provides a high power and high voltage load to various hipot tester to create the leakage current needed to calibrate various manufactures hipot testers.
-
product
LCR Meter
ET/QuadTech 1910/1920
The 1920 1 MHz LCR Meter is the most popular and designed to perform capacitance and impedance measurements on a variety of electronic components and materials over a frequency range from 20 Hz to 1 MHz. The1920 features programmable bias voltage from 1 mV to 2 V for biasing capacitors and other semiconductor devices during measurements.
-
product
Decade Resistor
esi / Tegam DB62
IET has improved the specifications on esi/Tegam's DB62 decade resistor. These Decade Resistors are primarily intended for precision measurement applications where their excellent accuracy of 0.01%, stability, and low zero resistance are important
-
product
Programmable Inductance Decade Box
PLS Series
The PLS Series is a broad line of high precision programmable decade inductors. They provide straight inductance in a wide selection of ranges, tolerances andratings. IET Labs also supplies custom combination substituters for capacitance and resistance as well as sources for voltage and current.
-
product
High Frequency Standard Capacitor
GenRad 1403 Series
The GenRad 1403 Standard Air Capacitors are stable, three-terminal standards in decimal values from 0.001 pF to 1000 pF. For measurement at 100 pF and below, a three terminal connection increases the accuracy by eliminating the uncertainty in the measurement introduced by the capacitances between the capacitor terminals and ground.
-
product
Micro-Ohmmeter
LOM-510A
The Micro-Ohmmeter has 4 digits, 0.02% basic accuracy and 1 resolution. The 4-terminal kelvin measurement connection minimizes lead resistance errors and 80 dB of ac noise rejection provides rock-steady readings even in noisy locations. The micro-ohmmeter comes with rugged 4-terminal test clips and a large selection of optional probes, clips and fixtures allowing attachment to any low-resistance unknown.