Validyne Engineering
A leading manufacturer of pressure transducers, pressure transmitters, signal conditioning in rack mount format and in portable units for field testing, and data acquisition systems with expandable chassis designs as well as PC based products for industrial and laboratory testing applications.
- (818) 886-8488
- (818) 886-6512
- sales@validyne.com
- 8626 Wilbur Avenue
Los Angeles, CA 91324
United States of America
-
product
Vehicle Pressure Acquisition System
VPAS
The Vehicle Pressure Acquisition System (VPAS) is designed to record and display up to 8 or 16 low pressure measurement points for the investigation of vehicle pressures within the passenger cabin, in HVAC ducting or with respect to the exterior of the vehicle. Validyne DP103 pressure sensors can be ordered with full scale ranges as low as 0.1 in H20 and up to 55 in H20.
-
product
Easy Sense Software
Easy Sense 2100 is available for use with the UPC2100. Easy Sense 225x is used with the Universal Data Acquisition System(UDAS) or the USB2251. The Software includes a GUI configuration utility that allows the user to set sensor type, gain range, channel, and all other input parameters. The configuration can be saved to non-volatile memory on the card so that the UP2100 or the UDAS can be used in embedded applications.
-
product
Variable Reluctance Pressure Sensor with All-Welded Construction
DP10
The DP10 Pressure Sensor, is designed for low and medium pressure measurements, to laboratory accuracy, of corrosive liquids and gases. In typical AC excited bridge circuits, this transducer delivers a full scale output of 30 mV per volt at 3kHz. The unit operates with carrier system including the Validyne CD15 since wave carrier demodulator and CD16 miniature DC input DC output carrier demodulator.
-
product
Portable Digital Manometer
PS309
Featured are an integral variable reluctance transducer, solid state electronics module, 3 digit liquid crystal display (LCD)* and battery pack with six 1.5V penlight cells for truly portable operation. The units can also be powered from an external DC power supply or AC battery eliminator (converter) module. The transducer features all corrosion resistant materials in contact with the pressure media (both ports in differential units), very low internal cavity volumes and ultra-low volumetric displacement with full-scale pressure excursion. Transducer calibration is unaffected by dielectric properties of the sensed fluid. Gauge and differential transducers may be disassembled and range changed by simple diaphragm replacement.
-
product
Low Range Low Cost OEM Differential Pressure Transducer
P17
The P17 OEM Low Range Low Cost pressure transducer features high sensitivity to very low pressures with full scales available down to 0.1 In H2O. Output signal is 5 Vdc and power can be +5 to +28 Vdc. Zero and Span adjustments are included. The P17 has a robust steel sensor construction.
-
product
Very Low Pressure Variable Reluctance Sensor
DP103
The Validyne DP103 is designed for exceedingly low differential pressure measurement applications where high accuracy is required under rough physical conditions. With full scale ranges down to -0.008 psid (-0.56cm H2O), this instrument is being used in the measurement of very low flow rates of gases where symmetrical pressure cavities are required for dynamic response. It is also used in very small leak detection and pressure null detection systems.
-
product
Universal Data Acquisition System
(UDAS/USB2250)
The Universal Data Acquisition System(UDAS) Sensor Interface provides real world data acquisition for your PC via the USB port. 16 sensor inputs in any mix or combination are accepted by the UDAS. No external signal conditioning is required. The UDAS includes configuration and data acquisition software.
-
product
Multi-Channel Carrier Demodulator
CD280
The CD280 Carrier Demodulator is a complete multi channel system in a small package which houses a plug-in power supply and 4 carrier demodulator circuit boards. The power supply provides regulated 5 Vac 5 kHz carrier power for Variable Reluctance and LVDT transducers , and the carrier demodulators demodulate and amplify the input signals to a 10 Vdc full-scale output. Zero and span adjustments are available for each channel. The system operates from 115 Vac, 50 to 400 Hz, line power.
-
product
ReCalibration and Post Calibration Software
SI58
The SI58 software allows the user to set zero and span as well as do full temperature compensation and linearity corrections for your Validyne USB pressure transducer. The SI58 provides everything needed to change the range of your transducer and calibrate it through the new full scale pressure. Corrections to non-linearity and temperature error are also possible. The SI58 software provides prompts to the operator for temperature and pressure points to achieve an accurate calibration.
-
product
Carrier Demodulator with LED Display
CD23/223
The CD23 and CD223 Digital Transducer Indicators are designed for use with variable reluctance and differential transformer transducers. The CD23 accepts input from a single transducer, and the CD223 accepts two switch-selectable inputs, with Zero and Span controls for each input. The indicators provide 5 Vrms, 5 kHz carrier excitation voltage to the transducer(s) and solid state circuitry to amplify, demodulate and filter the transducer output signals. A 3 1/2 digit front panel display is standard, with a 4 1/2 digit display optionally available.
-
product
Test and Measurement Grade Pressure Transducer for CAN Bus
P896
The P896 is a test and measurement grade pressure transducer for applications requiring high accuracy and outstanding performance through ambient temperature changes. The P896 is digitally compensated and corrected to provide high accuracy pressure measurement in a robust cylindrical form factor.
-
product
Network Sensor Interface for USB Pressure Transducers
SI314
The Validyne model SI314 is a network interface that connects our model P61 USB pressure Transducer to your smart phone or network web browser. The SI314 supports Ethernet and Wi-Fi connections and will display current pressure readings and transducer status on any web browser or via smart phone. The SI314 also displays the transducer temperature, date of calibration, model and serial numbers and these can be viewed wirelessly or by Ethernet connection. The SI314 makes your P61 accessible from anywhere in the world. Data logging of pressure data is configured via a web browser or smart phone and readings may be stored once per minute to once per hour. A thumb drive or memory card collects the data in comma separated file format(csv) for download to your computer. The data may also be accessed via the network. A graph of the data is also generated on request. A Twitter function allows pressure data to be tweeted from the SI314 at user-defined intervals. The transducer zero and span calibration adjustments are password protected and operated via browser buttons. No potentiometer adjustments are required to calibrate the P61 transducer. Contact our Sales Department for a link to the Demo!
-
product
Draft Range Trasmitter
DR800
The Validyne Model DR800 Draft Range Transmitter is designed exclusively for very low pressure measurement needs. It has a "true" full-scale range as low as 0.25" H2O, making it ideal for air flow control applications. It can be turned down to 0.1" H2O; higher full-scale ranges to 100" H2O are available. The DR800 offers 0.5% accuracy and an operating temperature range of -20F to +185F. The total combined temperature effects are less than 3%/100F.
-
product
Test and Measurement Pressure Transducer
P895
The P895 is designed for a wide variety of pressure measurements where high resistance to vibration and superior stability through temperature change is required. The zero and full-scale output calibrations are set by the potentiometer adjustments accessible from the top cover.
-
product
Pressure Sensor Interface
USB2251
The USB2251 Pressure Sensor Interface provides real-world data acquisition for your PC via the USB port. 8 calibrated variable reluctance pressure sensor inputs are accepted by the USB2251. No external signal conditioning is required.The USB2251 includes a connector panel for sensor cables, calibration constants for each sensor , configuration and data acquisition software. The USB2251 produces a floating-point value for all readings, directly in engineering units.The USB2251 can record pressure readings up to 5000 samples per second. Combined with the fast response of the Validyne VR pressure sensors, the USB2251 is ideal for transient pressure studies. The USB2251 is compatible with the following Validyne variable reluctance pressure sensors: AP10, DP103, DP10, DP45, DP15 DP360, DP215, and DP363. Each sensor is calibrated with the USB2251 at the factory and is ready to make measurements.