Validyne Engineering
A leading manufacturer of pressure transducers, pressure transmitters, signal conditioning in rack mount format and in portable units for field testing, and data acquisition systems with expandable chassis designs as well as PC based products for industrial and laboratory testing applications.
- (818) 886-8488
- (818) 886-6512
- sales@validyne.com
- 8626 Wilbur Avenue
Los Angeles, CA 91324
United States of America
Categories
-
product
Carrier Demodulator with LED Display
CD23/223
The CD23 and CD223 Digital Transducer Indicators are designed for use with variable reluctance and differential transformer transducers. The CD23 accepts input from a single transducer, and the CD223 accepts two switch-selectable inputs, with Zero and Span controls for each input. The indicators provide 5 Vrms, 5 kHz carrier excitation voltage to the transducer(s) and solid state circuitry to amplify, demodulate and filter the transducer output signals. A 3 1/2 digit front panel display is standard, with a 4 1/2 digit display optionally available.
-
product
Low Range Low Cost OEM Differential Pressure Transducer
P17
The P17 OEM Low Range Low Cost pressure transducer features high sensitivity to very low pressures with full scales available down to 0.1 In H2O. Output signal is 5 Vdc and power can be +5 to +28 Vdc. Zero and Span adjustments are included. The P17 has a robust steel sensor construction.
-
product
Pressure Sensor Kit for Changing Ranges
DP15TL
The wide range of diaphragms furnished eliminates expensive stocking of several transducers and offers the versatility of the differential type bi-directional transducer at a very low cost. The broad line pressure capability of this unit makes it useful in almost every laboratory application from flow to level measurement, vacuum to 3000 PSIG. The high output, when used with a carrier system such as the Model CD15 Sine Wave Carrier Demodulator or the CD12 Transducer Indicator, provides resolution equal to many secondary standard units.
-
product
Easy Sense Software
Easy Sense 2100 is available for use with the UPC2100. Easy Sense 225x is used with the Universal Data Acquisition System(UDAS) or the USB2251. The Software includes a GUI configuration utility that allows the user to set sensor type, gain range, channel, and all other input parameters. The configuration can be saved to non-volatile memory on the card so that the UP2100 or the UDAS can be used in embedded applications.
-
product
General Purpose Basic Carrier Demodulator
CD15
The CD15 Sine Wave Carrier Demodulator operates with variable reluctance transducers to provide a DC output signal for dynamics as well as steady state measurements. A 5kHz sine wave excitation is applied to the two inductance ratio arms of the transducer and the resulting output is demodulated and amplified using the latest integrated circuit techniques. The DC output is obtained from an active filter circuit and gives a uniform response from steady state to 1000 Hz. The low impedance sine wave excitation allows operation with the transducer located over 1,000 feet from the CD15.
-
product
Pressure Transducers with USB Interface
P61
The Validyne model P61 is a digital differential pressure transmitter designed for industrial pressure measurement applications. The on-board microprocessor provides high accuracy and improved stability in changing thermal environments. Communication and power via USB interface provides remote zero and span adjustment as well as digital pressure readings in engineering units. Drivers and software for the USB interface are included.
-
product
Test and Measurement Grade Pressure Transducer for CAN Bus
P896
The P896 is a test and measurement grade pressure transducer for applications requiring high accuracy and outstanding performance through ambient temperature changes. The P896 is digitally compensated and corrected to provide high accuracy pressure measurement in a robust cylindrical form factor.
-
product
Variable Reluctance Absolute Pressure Sensor
AP10
The AP10, Absolute Pressure Sensor, is designed for low and medium pressure measurements, to laboratory accuracy, of corrosive liquids and gases. In typical AC excited bridge circuits, this transducer delivers a full-scale output of 40 mV per volt at 3kHz. The unit operates with carrier systems including the Validyne CD15 sine wave carrier demodulator and CD16 miniature DC input DC output carrier demodulator to produce a high level analog DC output suitable for recording and control.
-
product
Data Acquisition PCI Card
UPC2100
The UPC2100 PCI Sensor Interface card provides real-world data acquisition and control for your PC. Up to 16 sensor inputs in any mix or combination are accepted by the UPC2100. No external signal conditioning is required. The UPC2100 includes configuration and data acquisition software and is compatible with C#, .NET, C++, Visual Basic, LabView.
-
product
Wet-Wet Differential Pressure Sensor
DP303
The DP303 features "take-apart" construction enabling the user to easily disassemble the unit for cleaning or to change full scale range by exchanging the sensing diaphragm. As noted from the Pressure Range/Diaphragm Selection Chart on the reverse side of this Data Sheet, a family of interchangeable diaphragms are available to cover virtually any full scale pressure range from 0.08 psid full scale to 5,000 psid full scale-all rated for operation at 5,000 psig line pressure!
-
product
Draft Range Trasmitter
DR800
The Validyne Model DR800 Draft Range Transmitter is designed exclusively for very low pressure measurement needs. It has a "true" full-scale range as low as 0.25" H2O, making it ideal for air flow control applications. It can be turned down to 0.1" H2O; higher full-scale ranges to 100" H2O are available. The DR800 offers 0.5% accuracy and an operating temperature range of -20F to +185F. The total combined temperature effects are less than 3%/100F.
-
product
Portable Carrier Demodulator with Digital Display
CD379
The CD379 is a portable, completely self contained digital transducer indicator. In addition to the front panel liquid crystal digital display, the unit also provides a 2 Vdc analog output suitable for recording, remote display or control purposes. The unit is for use with all variable reluctance transducers and features solid state electronics, 3 1/2 digit liquid crystal display and battery pack with six 1.5V penlight cells for truly portable operation. The unit can also be powered from an external DC power supply or AC battery eliminator (converter) module.
-
product
Ultra Low Pressure Transmitter
P532
Validyne's P532 Pressure Transmitters are ideally suited for measuring extremely low liquid and gas pressures in industrial applications. Full-scale differential pressure ranges from 0.10 H2O to 2 H2O with line pressure rating of 100 psig, and ranges of 2 H2O to 3200 psid with line pressures up to 3200 psig are offered. Gauge pressure ranges start at 0.10 H2O and absolute pressure from 0.08 psia full-scale. This unique design, which utilizes a diaphragm-type variable reluctance pressure sensor, provides many outstanding advantages including:
-
product
Test and Measurement Pressure Transducer
P895
The P895 is designed for a wide variety of pressure measurements where high resistance to vibration and superior stability through temperature change is required. The zero and full-scale output calibrations are set by the potentiometer adjustments accessible from the top cover.
-
product
Single-Channel DC Powered Carrier Demodulator
CD16
The CD16 Miniature Carrier Demodulator is designed to deliver a 0 to 5 Vdc output from a variable reluctance transducer and operate from unregulated 9 to 55 Vdc power. A square wave excitation of 5 kHz is furnished to the transducer and the solid state integrated circuit amplifier and demodulator converts the transducer signal to an analog dc output. Zero and Span adjustments are made through access holes in the case.