Validyne Engineering
A leading manufacturer of pressure transducers, pressure transmitters, signal conditioning in rack mount format and in portable units for field testing, and data acquisition systems with expandable chassis designs as well as PC based products for industrial and laboratory testing applications.
- (818) 886-8488
- (818) 886-6512
- sales@validyne.com
- 8626 Wilbur Avenue
Los Angeles, CA 91324
United States of America
-
product
Single-Channel USB Carrier Demodulator
CD17
The Validyne model CD17 is a USB-powered carrier demodulator for Validyne variable reluctance pressure sensors such as the DP15, DP45 and DP103. The CD17 allows any Validyne variable reluctance sensor to be used directly with a PC via the USB port. Communication and power via USB interface provides remote zero and span adjustment as well as digital pressure readings in mV/V. Drivers and software for the USB interface are included.
-
product
Ultra Low Pressure Transmitter
P532
Validyne's P532 Pressure Transmitters are ideally suited for measuring extremely low liquid and gas pressures in industrial applications. Full-scale differential pressure ranges from 0.10 H2O to 2 H2O with line pressure rating of 100 psig, and ranges of 2 H2O to 3200 psid with line pressures up to 3200 psig are offered. Gauge pressure ranges start at 0.10 H2O and absolute pressure from 0.08 psia full-scale. This unique design, which utilizes a diaphragm-type variable reluctance pressure sensor, provides many outstanding advantages including:
-
product
Variable Reluctance Pressure Sensor Capable of Range Changes
DP15
An easy-to-replace pressure-sensing diaphragm maximizes the system's functionality by making pressure measurements from 2.22" H2O to 3200 psi in one compact unit. Rugged and reliable, the DP15 pressure sensor provides superior accuracy for measuring low-pressure liquids and gasses, while it withstands the abuse of field and laboratory testing. The ability to change full scale ranges make the DP15 a very cost effective solution for applications that need different pressure ranges or university labs.
-
product
Vehicle Data Acquisition System
VDAS
The Validyne VDAS integrates all your data acquisition requirements for vehicle testing into one compact, rugged system. Up to 300 vehicle sensor channels can be accepted by the VDAS so that time consuming change-outs of instrumentation packages can be minimized. The same VDAS is easily shared by several test groups; system configurations can be saved and re-loaded as needed.
-
product
Very Low Pressure Variable Reluctance Sensor
DP103
The Validyne DP103 is designed for exceedingly low differential pressure measurement applications where high accuracy is required under rough physical conditions. With full scale ranges down to -0.008 psid (-0.56cm H2O), this instrument is being used in the measurement of very low flow rates of gases where symmetrical pressure cavities are required for dynamic response. It is also used in very small leak detection and pressure null detection systems.
-
product
HVAC Pressure Transmitter
DP850/851
The DP850/851 transmitters are designed for low pressure measurement in HVAC applications. The DP850 is available in full scale pressure ranges as low as 0.25 inH2O and the DP851 can be ranged to 0.025 inH2O full scale. Both models are available in 4-20 mA or 0 to +5 Vdc signal output options.
-
product
Test and Measurement Grade Vacuum Pressure Transducer
P897V
The P897V is designed for a wide variety of pressure measurements where high resistance to vibration and superior stability through temperature change is required. The zero and full-scale output calibrations are set by the potentiometer adjustments accessible from the top cover. The P897V is digitally compensated and corrected to provide high accuracy pressure measurement in a robust cylindrical form factor. Small vacuum pressures are accurately measured with full scale vacuum ranges as low as 2.22 InH2O.
-
product
General Purpose Basic Carrier Demodulator
CD15
The CD15 Sine Wave Carrier Demodulator operates with variable reluctance transducers to provide a DC output signal for dynamics as well as steady state measurements. A 5kHz sine wave excitation is applied to the two inductance ratio arms of the transducer and the resulting output is demodulated and amplified using the latest integrated circuit techniques. The DC output is obtained from an active filter circuit and gives a uniform response from steady state to 1000 Hz. The low impedance sine wave excitation allows operation with the transducer located over 1,000 feet from the CD15.
-
product
Digital Display for the Transducers and Transmitters
PS57
The PS57 is a combination power supply and 4 1/2 digit LED display for the P55/P855 family of pressure transducers and transmitters. The PS57 accepts 110 VAC power and provides the required 24 Vdc excitation for the transducer. The transducer signal is received and displayed directly in engineering units with bright 0.56 high red LEDs. The user can re-scale the display and set the decimal point by configuring internal jumpers. The analog output of the transducer, 5 Vdc or 4-20 mA, is available on rear-panel terminals.
-
product
High Line Pressure Variable Reluctance Pressure Sensor to 10,000 psid
DP360/DP363
The DP360 can be calibrated for a full scale as low as ±50 psid while withstanding high static line pressure. Low differential pressure may be measured at static pressures as high as 10,000 psig with a maximum 3% FS zero shift error.
-
product
Pressure Sensor Kit for Changing Ranges
DP15TL
The wide range of diaphragms furnished eliminates expensive stocking of several transducers and offers the versatility of the differential type bi-directional transducer at a very low cost. The broad line pressure capability of this unit makes it useful in almost every laboratory application from flow to level measurement, vacuum to 3000 PSIG. The high output, when used with a carrier system such as the Model CD15 Sine Wave Carrier Demodulator or the CD12 Transducer Indicator, provides resolution equal to many secondary standard units.
-
product
High Line Pressure Transducer with Digital Interface
P368
The Validyne model P368 is a digital differential pressure transmitter designed for high line pressures and industrial pressure measurement applications. Full scale ranges of 8 psid to 10,000 psid are available. The on-board microprocessor provides high accuracy and improved stability in changing thermal environments. Communication via RS485, USB or CanBus provides remote zero and span adjustment as well as digital pressure readings in engineering units.
-
product
Pressure Sensor Interface
USB2251
The USB2251 Pressure Sensor Interface provides real-world data acquisition for your PC via the USB port. 8 calibrated variable reluctance pressure sensor inputs are accepted by the USB2251. No external signal conditioning is required.The USB2251 includes a connector panel for sensor cables, calibration constants for each sensor , configuration and data acquisition software. The USB2251 produces a floating-point value for all readings, directly in engineering units.The USB2251 can record pressure readings up to 5000 samples per second. Combined with the fast response of the Validyne VR pressure sensors, the USB2251 is ideal for transient pressure studies. The USB2251 is compatible with the following Validyne variable reluctance pressure sensors: AP10, DP103, DP10, DP45, DP15 DP360, DP215, and DP363. Each sensor is calibrated with the USB2251 at the factory and is ready to make measurements.
-
product
Data Acquisition PCI Card
UPC2100
The UPC2100 PCI Sensor Interface card provides real-world data acquisition and control for your PC. Up to 16 sensor inputs in any mix or combination are accepted by the UPC2100. No external signal conditioning is required. The UPC2100 includes configuration and data acquisition software and is compatible with C#, .NET, C++, Visual Basic, LabView.
-
product
Carrier Demodulator with LED Display
CD23/223
The CD23 and CD223 Digital Transducer Indicators are designed for use with variable reluctance and differential transformer transducers. The CD23 accepts input from a single transducer, and the CD223 accepts two switch-selectable inputs, with Zero and Span controls for each input. The indicators provide 5 Vrms, 5 kHz carrier excitation voltage to the transducer(s) and solid state circuitry to amplify, demodulate and filter the transducer output signals. A 3 1/2 digit front panel display is standard, with a 4 1/2 digit display optionally available.