Com-Power Corporation
Com-Power Corporation has been a supplier of instrumentation for EMI / EMC Testing (electromagnetic compatibility), telecommunication ( Part68 ) and product safety ( UL / IEC CSA) testing since 1989.
- (949) 459-9600
- (949) 635-0329
- sales@com-power.com
- 1679 Placentia Avenue
Costa Mesa, California 92627
United States of America
-
product
Transient Limiters
Transient limiter LIT-153A and LIT-930A protects a spectrum analyzer input from high-level transients from the line impedance stabilization networks during EMC conducted emissions testing. It has a combined frequency range of 9 kHz to 30 MHz. The built in high pass filter helps reduce 50/60 Hz line feed through. (see application notes)
-
product
Near Field Probes
A typical emi emission test is performed using broadband EMC antennas such as biconical, log periodics, Combilogs and horns. These antennas usually placed at 1, 3 or 10 meter distance as required by the test specification. These is considered far field measurements and the emission limits are given for the specific distance by the specification. During EMI compliance measurements, the emissions levels from products are compared with these limits. If the product exceeds these limits it is considered failing. These tests are typically conducted in a open area test site IOATS) or inside an anechoic chamber.
-
product
Line Impedance Stabilization Networks
LISN
LISN stands for 'Line Impedance Stabilization Network'. Com-Power offers a line of LISNs developed for conducted emission testing according to the most commonly adopted EMC specifications like CISPR, FCC, ISO, EN, RTCA DO-160 and MIL-STD 461D. The LISN circuit is designed and constructed to meet the performance criteria given by these standards.
-
product
CDNs
T Series
The T series CDNs are for cables with unshielded balanced conductor pairs typically found in ISDN, DSL and Ethernet data transfer applications.
-
product
Absorbing Clamps
The absorbing clamps also known as ferrite clamps are used for measuring disturbance power on power input lines as well as other auxiliary I/O lines.
-
product
Immunity Testing Systems
CIS Series
The CIS series test systems are configured to perform conducted immunity testing according to IEC 61000-4-6. The system includes an ACS series power amplifier, coupling/decoupling Network (CDN), directional coupler, 150Ω to 50Ω adapters, power attenuators, cables and [optional] CSAT software. These systems, when properly configured, are capable of testing your products to all levels given in IEC 61000-4-6 up to 230 MHz. You can choose from three systems. Follow the links below for detailed information, including a comprehensive datasheet listing system specs.
-
product
Active Monopole Antenna
AM-741
The 41 inch Monopole antenna is required for making electric field emission measurements below 60 MHz per Military standards (MIL-STD-461) and FAA (DO-160) specifications. This antenna is for emissions measurements only. It cannot be used for transmitting. The Active Monopole antenna is generally used in a shielded room or in a screen room, with the equipment under test (EUT) placed on a metal ground plane. The 41 inch rod and the ground plane behave electrically as though a mirror image of the rod were located below the ground, and the ground removed. Since the stainless steel plate does not have enough surface area to mirror the entire 41 inch rod, it is bonded to the surrounding ground plane during use. The AM-741 is battery powered to prevent measurement errors that maybe caused by external power cables. The ANSI equivalent capacitance substitution (ECSM) method is the recommended method for calibrating AM-741 monopole antenna. The individual calibration data will be included with each antenna.
-
product
Spectrum Analyzer
SPA Series
The SPA-series high performance, low cost, easy to use, portable spectrum analyzers are ideal for a pre-compliance laboratory. All three models feature a wide frequency range and low noise floor to increase system sensitivity and system to noise ratio. An advanced, easy to use interface makes your work simple by putting the features you need at your fingertips.
-
product
Active Loop Antenna
AL-130R
Also known as Magnetic Loop Antenna, the AL-130R is compliant with CISPR 16-1-4. It is ideal for emissions measurements as required by various EMC standards such as FCC 18, CISPR 11, CISPR 13, CISPR 14, CISPR 32 and many more. The built-in, low-noise preamplifier, increases overall measurement sensitivity as well as the overall signal to noise ratio. As per ANSI C63.4-2014, the use of active loop antenna for compliance testing is permitted in a non-sheilded environment ONLY if the saturation indicator is continuously monitored during the course of testing. Com-Power’s Remote Antenna Interface (RAI-100) comes in very handy for this application. It is a compact controller which can be used to enable/ disable RF measurement circuit and monitor saturation and battery low conditions remotely via a fiber optic cable up to 30 mtrs in length.
-
product
CDNs
S Series
The S series CDNs are for shielded cables with single or multiple conductors. These CDNs are supplied with professional audio (RCA), D type and Centronics connectors.
-
product
Biconical Antennas
Biconical antennas are used for emissions and immunity testing to meet various EMC standards specified by FCC, CISPR and EN. The broadband characteristics of the biconical antenna make it a good choice for making sweep measurements and for automated measurement systems.
-
product
Dipole Antenna
AD-100
The Tuned Dipole Antenna model AD-100 is a reference antenna set specified in many EMC standards. It is used in the frequency range of 30 MHz to 1 GHz. This set consists of four baluns and was designed according to American National Standard C63.4. This reference antenna set is used for EMC test site calibrations and for calibrating other antennas, because it is considered a standard antenna according to ANSI C63.5 standard.
-
product
Antenna Kits
Com-Power offers five portable antenna kits suitable for offsite EMC testing. These kits are supplied with a custom hard plastic carrying case which has individual compartments for all the included items.
-
product
Combilog Antenna
AC-220
The AC-220 Combilog antenna is for EMC emission and immunity up to 2 GHz.. It combines the electrical properties of two antenna (biconical and Log ). It reduces overall testing time by 20 - 30% due to antenna switching. It is Optimized for emission measurements, but can handle up to 500 Watt CW, making it suitable for most immunity measurements . Each antenna is individually calibrated at 10 meters and the data included the purchase price.
-
product
Surge Generator
SGTEL-168
The SGTEL-168 is a versatile surge generator designed to simulate all the environmental surge transients as described in FCC TIA-968-B (formerly known as Part 68) and Industry Canada CS03 standard. It provides a single box solution Type A, Type B (metallic and longitudinal) and Powerline surges. These surges simulate the effect of lightning on telecom equipment under test. So it is also referred to as Lightning Simulator. The electromagnetic energy from the lightning couples into the equipment by powerline or telecom cable exposed to the lightning directly or indirectly. This model is an upgraded version of SG-168 with windows software control and a user friendly front panel for manual operation.