Since 1977, Dexter Research has been the preferred provider of infrared thermopile detectors for science and industry. Today we offer the world's largest selection of thermopile-based solutions including high-quality, high-output Bismuth-Antimony thin film and silicon-based infrared-sensing thermopile detectors. We offer standard detectors in high volumes. We also customize detectors for specific needs. Integrated modules serve as complete sensing subsystems.
- +1 (734) 426-3921
- +1 (734) 426-5090
- info@dexterresearch.com
- 7300 Huron River Drive
Dexter, MI 48130
United States of America
-
product
Thermacon Request to Exit Sensor
T-80 and S-80
These units are designed for easy concealed installation in suspended ceilings or on an enclosed metal electrical box is acceptable for use in air handling areas. In addition to the four standard interchangeable detection patterns, others may be custom made.
-
product
Request to Exit Sensor - Motion/Presence Sensors
Thermacon - Request to Exit Sensor, Concealed Passive Infrared Motion SensorA concealed and totally silent passive infrared (PIR) motion sensor that detects the presence of natural body heat and activates a relay. Relay activation begins when the detection area is entered and remains on for the duration of the preset relay timing. The unit is designed for concealed and easy installation in suspended ceilings. Four interchangeable detection patterns are standard with each unit. Units accept a power supply range of 12 to 24 volts AC or DC
-
product
Imaging
SLA64 (Preliminary)
A 1 x 64 element silicon-based thermopile array. Each active area is 0.45mm x 2.0mm with a time constant of 42ms and a low Temperature Coefficient of Responsivity of -0.06%/C. It is packaged in a 68-pin QIP. Includes internal 30k 5% NTC chip thermistor provides ambient package temperature measurement. See Thermistor Options p/n: MT04.
-
product
Thin Film Based Thermopile Detector: 4 Channels
2M Quad
A four-channel thin-film thermopile in a TO-8 package. Each active area is 2mm x 2mm. Offers the world's highest 4-channel sensitivity with exceptional signal-to-noise performance in a TO-8 package. Internal aperture minimizes channel-to-channel crosstalk while increasing sensitivity.
-
product
Thin Film Based Thermopile Detector: 1 Channel
DR46 Compensated
A one-channel compensated thin-film thermopile in a TO-8 package. The active area and compensating element area are 4mm x 0.6mm each. Offers high output with very good signal-to-noise ratio. Internal aperture minimizes channel-to-channel crosstalk increasing sensitivity.
-
product
Temperature Measurement IR Sensors & Detectors
ST60 TO-18
A single-channel silicon-based thermopile provides lowest cost solutions in a small active area of 0.61mm x 0.61mm in a small TO-18 package. Time constant of 18ms with Nitrogen encapsulation gas. Delivers a very low Temperature Coefficient of Responsivity of -0.04%/C. This detector has a very short thermal shock response to ambient temperature change.
-
product
Security/Detection
If your design challenge is to create the best motion sensor or motion detector - fire sensor or fire detector, smoke sensor or smoke detector - you've come to the right company. Dexter's sensor technologies are at multiple fronts today, reducing the threat of combat on land, sea and air. Yet the industry leading advantages of Dexter sensors - low cost, high sensitivity, low energy consumption and long life - make them the perfect motion sensor for home, office and facility applications. Dexter thin-film and silicon detectors can target precise threats, whether defined by movement, temperature or body mass. Intensive MIL-STD-883H testing performed by Trialon Corporation, an independent testing facility, confirm that Dexter Research's silicon-based temperature sensor detectors meet the same rugged requirements of 1,000G's for mechanical shock and 30G's in random vibration for which our thin-film detectors are famous. Download Dexter's report here (PDF).
-
product
Digital Solutions
Digital ST60 Thermopile (Preliminary)
A single channel silicon- based thermopile in a TO-5 package that includes integrated electronics which incorporate an industry standard digital SMBus interface. The small active area size is 0.61mm x 0.61mm.
-
product
Temperature Measurement IR Sensors & Detectors
ST60 LCC
A single-channel silicon-based thermopile in a LCC package for surface mount assembly in a small active area of 0.61mm x 0.61mm. Time constant of 18ms with Nitrogen encapsulation gas. Delivers a very low Temperature Coefficient of Responsivity of -0.04%/C. This detector has a very short thermal shock response to ambient temperature chang
-
product
Gas Analysis
Our infrared gas detectors provide superior sensitivity and reliability that may be translated into a more effective early warning system when monitoring atmospheres for gases at trace levels. Our technology also offers the opportunity to perform sophisticated gas analysis. One example: To assure personal safety during a medical procedure, our gas detectors deliver a precise monitoring of the ratio of exhaled gases of a hospital patient who is under general anesthesiology. Another example, no canary need die in a mine if Dexter gas detectors are installed on the job. Infrared lead detectors, whether mobile or mounted, can be a critical element in your health and safety strategy at home and on the job, whatever life forms it is your responsibility to protect.
-
product
Digital Solutions
Digital ST60 Dual Thermopile (Preliminary)
A two channel silicon- based thermopile in a TO-5 package that includes integrated electronics which incorporate an industry standard digital SMBus interface. Each small active area size is 0.61mm x 0.61mm.
-
product
Miniature Amplifier PCB
Sized for single channel TO-5 packages and electrically compatible with all Dexter Research Center detectors. Available in three amplifier gains: 300, 500 and 1,000 providing convenient buffering and pre-amplification of thermopile signal. Facilitates fast R&D startup time that can be integrated into your prototypes or final system design.
-
product
Security/Detection
DR26
A two-channel thin-film thermopile that offers low noise in a TO-5 package. Each small active area is 2mm x 0.6mm. This is our lowest noise-voltage two-channel detector.
-
product
Laser Power and Targeting
ST60 Quad
A four-channel silicon-based thermopile detector in a TO-5 package. Each small active area size is 0.61mm x 0.61mm. This is our lowest-cost and fastest time constant four-channel detector. It delivers a time constant of 18ms with Nitrogen encapsulation gas combined with a very low Temperature Coefficient of Responsivity of -0.04%/C. This detector has a very short thermal shock response to ambient temperature change.