BAUR
The BAUR testing and measurement technology prevents damage to networks and systems, allows for accurate planning of investments for maintenance and locates faults as precisely and quickly as possible. For the reliability of your networks and systems.
- +43 5522 49410
- +43 5522 49413
- headoffice@baur.eu
- Raiffeisenstraße 8
Sulz, 6832
Austria
-
Product
Partial Discharge Inductor
Tracy
-
Cable testing and diagnostics with the BAUR tracy. The BAUR tracy partial discharge inductor induces a signal at the apparent fault location in the cable from outside. In combination with any PD measurement system, e.g., PHG TD/PD, the induced signal can be located and compared with the result of the partial discharge pre-location. The partial discharge location can thus be determined precisely.* Portable, battery-operated signal coupling device* Suitable for cables and cable accessories* Inductive signal coupling* Aviods costly, unnecessary replacements of PD-free cable accessories
-
Product
Surge Voltage Generator
SSG 500
-
Cable fault location with the BAUR SSG 500. The SSG 500 surge voltage generator is arranged in a 19'' housing. Maximum safety is achieved with the electrical safety control unit, the automatic discharge unit, the fully enclosed design and separate protection and system earth.* 6 output voltages up to max. 16 kV available* Electromagnetically actuated surge switch* Preselectable surge energy: 288 / 512 Ws (in all voltage ranges)* Automatic discharge unit
-
Product
VLF Diagnostics System
PHG 70 TD
-
Cable testing and diagnostics with the BAUR PHG 70 TD. The combination of the PHG 70 programmable test generator with the BAUR dissipation factor measurement system produces the cable testing and diagnostics system PHG TD. It is operated via PC control. Dissipation factor measurement and diagnostic testing sequences can be programmed in the menu, after which the dissipation factor measured values are automatically determined in various voltage steps and a final evaluation is conducted.* Biggest dynamic range of tan delta measured values from 1 to 10-4 with a cable capacitance >10 nF to 20 uF* High resolution +/- 1x10-5 applicable even in new PE/XLPE cables* Insensitive against interferences due to complete mains separation* Lowest time required for assessing a medium-voltage cable (3-phase approx. 1 hour)
-
Product
High-Voltage Test Device
PGK 110 / 5 HB
-
Cable testing and diagnostics with the BAUR PGK HB. There are hardly any other longer-lasting, more robust and cost-effective testing devices than the two-piece high-voltage test devices from the PGK HB series. They generate continuous adjustable test voltages with mains frequency or optionally DC with positive or negative polarity. The display instruments for current and voltage, the safety control unit and the regulating transformer for the voltage are integrated in the operating unit.* Testing as DC or Dc testing device* Polarity of the DC voltage can easily be reversed* Robust and durable
-
Product
Cable Locator
CL 20
-
Cable fault location with the BAUR CL 20. The CL 20 cable locator comprising a transmitter and a receiver is used to determine the exact location of cables and metal pipes. The ability to determine laying depths of up to 4.5 m and to measure signal currents at the touch of a button allows you to obtain reliable information on the position of the cable within the shortest time.* Fast and exact location of position and laying depth of cables* Intuitive operation – no special measurement knowledge required* Lightweight and manageable
-
Product
Time Domain Reflectometer
IRG 2000
-
Cable fault location with the BAUR IRG 2000. The IRG 2000 impulse reflection measurement unit or time domain reflectometer is a handy, easy to carry device for single-phase cable fault pre-location. It is used in combination with a surge voltage generator on low-, medium- and high-voltage cables 0 - 65 km in length. It can also be used on live cables carrying voltage up to 400 V.* Easy and quick cable fault location* Light, compact and manageable* Main unit for the tried-and-tested pre-location method* Ideal for integration in measurement systems
-
Product
Portable PD Diagnostics System
PD-TaD 60
-
The PD TaD 60 portable PD Diagnostics system is used in combination with a BAUR VLF generator frida for carrying out partial discharge measurement and location.* Comprehensive 360° cable analysis – with parallel partial discharge and dissipation factor measurement* Time-optimised and safe cable condition evaluation* The lightest and most compact PD measuring device up to 60 kVpeak* Developed for portable use on site
-
Product
Time Domain Reflectometer
IRG 4000
-
Cable fault location with the BAUR IRG 4000. The IRG 4000 time domain reflectometer is integrated in BAUR cable fault location systems and is used in combination with the system software for locating cable faults in single and three-phase cable systems. Thanks to the novel operational concept, cable faults can be located more rapidly and easily with IRG 4000. The high-performance industrial PC and improved measurement parameters allow for a precise cable fault location in all cable types. The well-proven and continuously enhanced methods are available for the cable fault location as well as the newly developed Conditioning SIM/MIM** method which makes it even more effective and quick to locate wet cable faults that are difficult to detect. The SIM/MIM technology with 20 reflection measurements per HV pulse allows for selecting the best reflection image for a very precise determination of the fault distance.* Easy operation thanks to intuitive operational concept*Maximum precision with high resolution and sampling rate*Precise fault location methods for every type of fault
-
Product
Search Receiver
KMF 1
-
Cable fault location with the BAUR KMF 1. The KMF 1 search receiver is used according to the step voltage method. The cable line is scanned with two measurement probes that can be dismantled during transport. The battery-operated device is also suitable for locating multiple consecutive sheath faults.* Battery mode* Zero point compensation* accurate location of cable sheath faults* battery test
-
Product
Cable Sheath Testing and Fault Location System
Shirla
-
Cable fault location with the BAUR shirla. Shirla the fault location system is used for cable and cable sheath testing as well as for pre-location and pinpointing of cable faults. The pre-location based on the measuring bridge principle according to Murray and Glaser that is designed especially for power cables, also enables pre-location for control and lighting cables. Null balance and evaluation take place automatically.* Cable and cable sheath testing up to 10 kVC* Resistance measurement* Cable and cable sheath fault pre-location with precision measuring bridge* Adjustable cable sections that can be defined with length, conductor cross-section and material respectively and can be considered in the distance calculation
-
Product
Surge Voltage Generator
SSG 1100
-
Cable fault location with the BAUR SSG 1100. Surge voltage generators are used for pre-location and pinpointing of high- and low-resistive as well as intermittent faults in power cables. The energy stored in a high-voltage capacitor is released at regular intervals or as DC voltage. The thus generated acoustic signal at the fault position can be recorded with a ground microphone and a universal receiver.* High surge voltage up to 32 kV* Continuously adjustable voltage* Voltage monitoring through kV meters with 3 measuring ranges* Automatic discharge unit
-
Product
Surge Voltage Generator
SSG 3000
-
Cable fault location with the BAUR SSG 3000. Surge voltage generators are used for pre-location and pinpointing of high- and low-resistive as well as intermittent faults in power cables. The energy stored in a high-voltage capacitor is released at regular intervals or as DC voltage. The thus generated acoustic signal at the fault position can be recorded with a ground microphone and a universal receiver.* High surge voltage up to 32 kV* Continuously adjustable voltage* Voltage monitoring through kV meters with 3 measuring ranges* high surge energy in each voltage range
-
Product
VLF Testing and Diagnostics Unit
Viola TD
-
Cable testing and diagnostics with the BAUR viola TD. The portable and high performance high-voltage testing and diagnostics device is available in two different configurations:viola: Used for cable and cable sheath testing of electrical equipment and medium-voltage cables up to 35 kV. Another function is insulation testing on electrical equipment. viola TD: Expands the functional scope of viola with the tan delta diagnostics and Monitored Withstand Test (MWT) that combines the cable testing and dissipation factor measurement. This allows for an accurate and comprehensive assessment of the cable condition.* Cable testing and dissiation factor diagnostics in one device* High performance and compact* Easy and quick test setup* Automatic testing and diagnostic sequences
-
Product
Surge Voltage Generator
SSG 1500
-
Cable fault location with the BAUR SSG 1500. Surge voltage generators are used for pre-location and pinpointing of high- and low-resistive as well as intermittent faults in power cables. The energy stored in a high-voltage capacitor is released at regular intervals or as DC voltage. The thus generated acoustic signal at the fault position can be recorded with a ground microphone and a universal receiver.* High surge voltage up to 32 kV* Continuously adjustable voltage* Voltage monitoring through kV meters with 3 measuring ranges* Automatic discharge unit
-
Product
High-Voltage Test Device
PGK 110 HB
-
Cable testing and diagnostics with the BAUR PGK HB. There are hardly any other longer-lasting, more robust and cost-effective testing devices than the two-piece high-voltage test devices from the PGK HB series. They generate continuous adjustable test voltages with mains frequency or optionally DC with positive or negative polarity. The display instruments for current and voltage, the safety control unit and the regulating transformer for the voltage are integrated in the operating unit.* Testing of medium- and high-voltage cables* DC voltage testing of up to 110 kV output voltage with positive or negative polarity* AC voltage testing - up to 80 kV for switchgear, busbars and insulating elements* Easy-to-maintain 2-piece design













