Universal Converter
C8000
Multi channel converter for all optek photometric and conductivity sensors and electrochemical pH electrodes. Flexible configuration of sensors, measuring ranges, units and product specific setups make the C8000 converter series a powerful device in process monitoring in both conventional and single-use systems.
-
product
Absorption Probe
ASD25-N
ASD25-N probe for direct installation into bioreactors, pipelines and vessels measuring absorption, cell growth and optical density of various liquid samples under sanitary process environments. The probe is suited for Sterilization In Place (SIP) / and Clean In Place (CIP) procedures.
-
product
Absorption Probe
ASD12-N
The ASD12-N absorption probe has a durable LED light source for direct installation into laboratory bioreactors and disposable bioreactors for measuring cell growth and optical density. The probe is available in three different lengths to fit any vessel and is suited for sterilization / autoclaving procedures.
-
product
Electroplating Bath Analyzer
optek’s electroplating analyzers are inline devices designed to measure plating solution’s metal concentration in real time. These analyzers can be designed to accommodate virtually any concentration range. Operationally, the analyzer passes a white light beam through the plating solution to be monitored. Then, light absorbance is measured at two distinct wavelengths, and the difference in light absorbance between the two wavelengths is equated to a plating solution concentration.
-
product
Conductivity Sensor
ACF60-35
Knowing the conductivity of liquid samples is a key parameter to control product quality throughout the production process. The optek ACF60 conductivity sensor fulfils technical requirements of international regulations for reliable measurements ensuring quality and consistency.
-
product
Photometric Converter
C4000
The C4000 converter is a multi channel controller capable of operating all optek photometric sensors. The C4000 converter allows for easy programming and operation, and can supply up to four real time configurable 4-20 mA output values correlated to any units of measure. The C4000 offers configurable relay alarms, can record and download process data, and can operate up to four sensors simultaneously.
-
product
VIS/NIR Sensor
AF26
The AF26 is a high precision dual channel color sensor for inline operation; the secondary wavelength is designed to compensate the desired light absorbance measurement from any undesired light scattering influence, such as suspended solids, gas bubbles, immiscible fluids or window fouling. The AF26 sensor’s output can be correlated to almost any color scale including APHA and Hazen.
-
product
Turbidity Meter
TF16-N
The TF16-N is a high precision turbidity meter for installation into pipelines measuring scattered and unscattered light at two independent angles in various liquid process streams. The ratio of scattered to un-scattered light can then be correlated.
-
product
Saybolt Color Analyzer
optek’s Saybolt color analyzer is a dual wavelength light absorption sensor. Operationally, the sensor passes a white light beam through the stream to be monitored, where light absorbance is measured at two distinct wavelengths. The measuring wavelength is set to focus on or near the peak absorbance point of the “yellowness” curve, while the secondary wavelength is chosen to compensate for any influence due to light scattering (window fouling, particulate, immiscible fluids, gas bubbles, etc.). Together, the sensor yields a repeatable and reliable true color number without any sample conditioning.
-
product
UV Analyzer
AF45
The AF45 is a high precision UV light absorption analyzer designed for inline operation to provide accurate concentration measurements with remarkable repeatability, linearity and resolution. Wavelength and optical path length are individually configurable for extremely high accuracy to meet process control requirements.
-
product
Chlorine Dioxide Analyzer
optek’s chlorine dioxide (ClO2) analyzers are inline devices designed to measure real time ClO2 solution strength and/or ClO2 gas concentration . These analyzers can be designed to accommodate virtually any measuring range regardless of the stream’s phase. Operationally, the analyzer passes a white light beam through the ClO2 stream to be monitored, where light absorbance is measured at two distinct wavelengths.
-
product
Oil In Cooling Water Monitor
The ability to detect oil in water is important for many industrial processes involving cooling water or heat exchangers. For example, electric generating stations often use natural sources of water such as lakes and rivers to cool generator lube oil systems. The lube oil is cooled in a heat exchanger where the lube oil and cooling water are in isolated streams.
-
product
UV Analyzer
AF46
The AF46 is a dual wavelength, high precision UV light absorption analyzer designed for inline operation to provide accurate concentration measurements with remarkable repeatability, linearity and resolution. Wavelength and optical path length can be individually configured to specific requirements for the highest accuracy.
-
product
Turbidity Sensor
TF56-N
The TF56-N sensor is an inline real-time device designed to measure light absorbance at 11° caused by interaction with process turbidity. As an NIR light beam is passed through a dynamic process stream, the sensor simultaneously measures the amount of light scattered at 11° and the remaining amount of un-scattered light at 0°.
-
product
Turbidity Probe
AS56-N
AS56-N is a probe for direct installation into pipelines and vessels measuring NIR light absorption (Turbidity or Solids Concentration) in various liquid flow streams. Two optical path length choices allow the measurement range to meet the process control requirements.